Monday, September 16, 2019

Fddi and Cddi

C H A P T E R 8 Chapter Goals †¢ †¢ †¢ †¢ Provide background information about FDDI technology. Explain how FDDI works. Describe the differences between FDDI and Copper Distributed Data Interface (CDDI). Describe how CDDI works. Fiber Distributed Data Interface Introduction The Fiber Distributed Data Interface (FDDI) specifies a 100-Mbps token-passing, dual-ring LAN using fiber-optic cable. FDDI is frequently used as high-speed backbone technology because of its support for high bandwidth and greater distances than copper. It should be noted that relatively recently, a related copper specification, called Copper Distributed Data Interface (CDDI), has emerged to provide 100-Mbps service over copper. CDDI is the implementation of FDDI protocols over twisted-pair copper wire. This chapter focuses mainly on FDDI specifications and operations, but it also provides a high-level overview of CDDI. FDDI uses dual-ring architecture with traffic on each ring flowing in opposite directions (called counter-rotating). The dual rings consist of a primary and a secondary ring. During normal operation, the primary ring is used for data transmission, and the secondary ring remains idle. As will be discussed in detail later in this chapter, the primary purpose of the dual rings is to provide superior reliability and robustness. Figure 8-1 shows the counter-rotating primary and secondary FDDI rings. Internetworking Technologies Handbook 1-58705-001-3 8-1 Chapter 8 FDDI Transmission Media Fiber Distributed Data Interface Figure 8-1 FDDI Uses Counter-Rotating Primary and Secondary Rings Primary Secondary FDDI Concentrator WAN Standards FDDI was developed by the American National Standards Institute (ANSI) X3T9. 5 standards committee in the mid-1980s. At the time, high-speed engineering workstations were beginning to tax the bandwidth of existing local-area networks (LANs) based on Ethernet and Token Ring. A new LAN media was needed that could easily support these workstations and their new distributed applications. At the same time, network reliability had become an increasingly important issue as system managers migrated mission-critical applications from large computers to networks. FDDI was developed to fill these needs. After completing the FDDI specification, ANSI submitted FDDI to the International Organization for Standardization (ISO), which created an international version of FDDI that is completely compatible with the ANSI standard version. FDDI Transmission Media FDDI uses optical fiber as the primary transmission medium, but it also can run over copper cabling. As mentioned earlier, FDDI over copper is referred to as Copper-Distributed Data Interface (CDDI). Optical fiber has several advantages over copper media. In particular, security, reliability, and performance all are enhanced with optical fiber media because fiber does not emit electrical signals. A physical medium that does emit electrical signals (copper) can be tapped and therefore would permit unauthorized access to the data that is transiting the medium. In addition, fiber is immune to electrical interference from radio frequency interference (RFI) and electromagnetic interference (EMI). Fiber historically has supported much higher bandwidth (throughput potential) than copper, although recent technological advances have made copper capable of transmitting at 100 Mbps. Finally, FDDI allows 2 km between stations using multimode fiber, and even longer distances using a single mode. FDDI defines two types of optical fiber: single-mode and multimode. A mode is a ray of light that enters the fiber at a particular angle. Multimode fiber uses LED as the light-generating device, while single-mode fiber generally uses lasers. Internetworking Technologies Handbook 8-2 ct840801 1-58705-001-3 Chapter 8 Fiber Distributed Data Interface FDDI Specifications Multimode fiber allows multiple modes of light to propagate through the fiber. Because these modes of light enter the fiber at different angles, they will arrive at the end of the fiber at different times. This characteristic is known as modal dispersion. Modal dispersion limits the bandwidth and distances that can be accomplished using multimode fibers. For this reason, multimode fiber is generally used for connectivity within a building or a relatively geographically contained environment. Single-mode fiber allows only one mode of light to propagate through the fiber. Because only a single mode of light is used, modal dispersion is not present with single-mode fiber. Therefore, single-mode fiber is capable of delivering considerably higher performance connectivity over much larger distances, which is why it generally is used for connectivity between buildings and within environments that are more geographically dispersed. Figure 8-2 depicts single-mode fiber using a laser light source and multimode fiber using a light emitting diode (LED) light source. Figure 8-2 Light Sources Differ for Single-Mode and Multimode Fibers Laser light source Single mode Multimode LED light source ct840802 FDDI Specifications FDDI specifies the physical and media-access portions of the OSI reference model. FDDI is not actually a single specification, but it is a collection of four separate specifications, each with a specific function. Combined, these specifications have the capability to provide high-speed connectivity between upper-layer protocols such as TCP/IP and IPX, and media such as fiber-optic cabling. FDDI’s four specifications are the Media Access Control (MAC), Physical Layer Protocol (PHY), Physical-Medium Dependent (PMD), and Station Management (SMT) specifications. The MAC specification defines how the medium is accessed, including frame format, token handling, addressing, algorithms for calculating cyclic redundancy check (CRC) value, and error-recovery mechanisms. The PHY specification defines data encoding/decoding procedures, clocking requirements, and framing, among other functions. The PMD specification defines the characteristics of the transmission medium, including fiber-optic links, power levels, bit-error rates, optical components, and connectors. The SMT specification defines FDDI station configuration, ring configuration, and ring control features, including station insertion and removal, initialization, fault isolation and recovery, scheduling, and statistics collection. FDDI is similar to IEEE 802. 3 Ethernet and IEEE 802. 5 Token Ring in its relationship with the OSI model. Its primary purpose is to provide connectivity between upper OSI layers of common protocols and the media used to connect network devices. Figure 8-3 illustrates the four FDDI specifications and their relationship to each other and to the IEEE-defined Logical Link Control (LLC) sublayer. The LLC sublayer is a component of Layer 2, the MAC layer, of the OSI reference model. Internetworking Technologies Handbook 1-58705-001-3 8-3 Chapter 8 FDDI Station-Attachment Types Fiber Distributed Data Interface Figure 8-3 FDDI Specifications Map to the OSI Hierarchical Model Logical link control Media access control FDDI standards Physical layer protocol Station management Physical layer medium ct840803 FDDI Station-Attachment Types One of the unique characteristics of FDDI is that multiple ways actually exist by which to connect FDDI devices. FDDI defines four types of devices: single-attachment station (SAS), dual-attachment station (DAS), single-attached concentrator (SAC), and dual-attached concentrator (DAC). An SAS attaches to only one ring (the primary) through a concentrator. One of the primary advantages of connecting devices with SAS attachments is that the devices will not have any effect on the FDDI ring if they are disconnected or powered off. Concentrators will be covered in more detail in the following discussion. Each FDDI DAS has two ports, designated A and B. These ports connect the DAS to the dual FDDI ring. Therefore, each port provides a connection for both the primary and the secondary rings. As you will see in the next section, devices using DAS connections will affect the rings if they are disconnected or powered off. Figure 8-4 shows FDDI DAS A and B ports with attachments to the primary and secondary rings. Internetworking Technologies Handbook 8-4 1-58705-001-3 Chapter 8 Fiber Distributed Data Interface FDDI Fault Tolerance Figure 8-4 FDDI DAS Ports Attach to the Primary and Secondary Rings Primary Primary Port A Port B Secondary Secondary FDDI DAS An FDDI concentrator (also called a dual-attachment concentrator [DAC]) is the building block of an FDDI network. It attaches directly to both the primary and secondary rings and ensures that the failure or power-down of any SAS does not bring down the ring. This is particularly useful when PCs, or similar devices that are frequently powered on and off, connect to the ring. Figure 8-5 shows the ring attachments of an FDDI SAS, DAS, and concentrator. Figure 8-5 A Concentrator Attaches to Both the Primary and Secondary Rings FDDI Concentrator DAS SAS SAS FDDI Fault Tolerance FDDI provides a number of fault-tolerant features. In particular, FDDI’s dual-ring environment, the implementation of the optical bypass switch, and dual-homing support make FDDI a resilient media technology. ct840805 Internetworking Technologies Handbook 1-58705-001-3 ct840804 8-5 Chapter 8 FDDI Fault Tolerance Fiber Distributed Data Interface Dual Ring FDDI’s primary fault-tolerant feature is the dual ring. If a station on the dual ring fails or is powered down, or if the cable is damaged, the dual ring is automatically wrapped (doubled back onto itself) into a single ring. When the ring is wrapped, the dual-ring topology becomes a single-ring topology. Data continues to be transmitted on the FDDI ring without performance impact during the wrap condition. Figure 8-6 and Figure 8-7 illustrate the effect of a ring wrapping in FDDI. Figure 8-6 A Ring Recovers from a Station Failure by Wrapping Station 1 MAC B A Station 4 Ring wrap Ring wrap Station 2 A MAC B B MAC A A B Failed station Station 3 Internetworking Technologies Handbook 8-6 1-58705-001-3 Chapter 8 Fiber Distributed Data Interface FDDI Fault Tolerance Figure 8-7 A Ring also Wraps to Withstand a Cable Failure Station 1 MAC B A Station 4 Ring wrap Station 2 A MAC B B MAC A Failed wiring Ring wrap A B Station 3 When a single station fails, as shown in Figure 8-6, devices on either side of the failed (or powered-down) station wrap, forming a single ring. Network operation continues for the remaining stations on the ring. When a cable failure occurs, as shown in Figure 8-7, devices on either side of the cable fault wrap. Network operation continues for all stations. It should be noted that FDDI truly provides fault tolerance against a single failure only. When two or more failures occur, the FDDI ring segments into two or more independent rings that are incapable of communicating with each other. Optical Bypass Switch An optical bypass switch provides continuous dual-ring operation if a device on the dual ring fails. This is used both to prevent ring segmentation and to eliminate failed stations from the ring. The optical bypass switch performs this function using optical mirrors that pass light from the ring directly to the DAS device during normal operation. If a failure of the DAS device occurs, such as a power-off, the optical bypass switch will pass the light through itself by using internal mirrors and thereby will maintain the ring’s integrity. The benefit of this capability is that the ring will not enter a wrapped condition in case of a device failure. Figure 8-8 shows the functionality of an optical bypass switch in an FDDI network. When using the OB, you will notice a tremendous digression of your network as the packets are sent through the OB unit. Internetworking Technologies Handbook 1-58705-001-3 ct840807 MAC 8-7 Chapter 8 FDDI Fault Tolerance Fiber Distributed Data Interface Figure 8-8 The Optical Bypass Switch Uses Internal Mirrors to Maintain a Network Station 1 Station 1 B A B A Failed station Optical bypass switch â€Å"normal configuration† Station 4 A B Optical bypass switch â€Å"bypassed configuration† Ring does not wrap Station 2 A B Station 2 A B Station 4 A B A B A B Station 3 Station 3 Dual Homing Critical devices, such as routers or mainframe hosts, can use a fault-tolerant technique called dual homing to provide additional redundancy and to help guarantee operation. In dual-homing situations, the critical device is attached to two concentrators. Figure 8-9 shows a dual-homed configuration for devices such as file servers and routers. Internetworking Technologies Handbook 8-8 1-58705-001-3 Chapter 8 Fiber Distributed Data Interface FDDI Frame Format Figure 8-9 A Dual-Homed Configuration Guarantees Operation Concentrator Concentrator File servers Routers One pair of concentrator links is declared the active link; the other pair is declared passive. The passive link stays in backup mode until the primary link (or the concentrator to which it is attached) is determined to have failed. When this occurs, the passive link automatically activates. FDDI Frame Format The FDDI frame format is similar to the format of a Token Ring frame. This is one of the areas in which FDDI borrows heavily from earlier LAN technologies, such as Token Ring. FDDI frames can be as large as 4,500 bytes. Figure 8-10 shows the frame format of an FDDI data frame and token. Figure 8-10 The FDDI Frame Is Similar to That of a Token Ring Frame Data frame Preamble Start delimiter Frame control Destination address Source address ct840809 Data FCS End delimiter Frame status Token Preamble Start delimiter Frame control End delimiter FDDI Frame Fields The following descriptions summarize the FDDI data frame and token fields illustrated in Figure 8-10. Internetworking Technologies Handbook 1-58705-001-3 8-9 Chapter 8 Copper Distributed Data Interface Fiber Distributed Data Interface †¢ †¢ †¢ †¢ †¢ †¢ †¢ Preamble—Gives a unique sequence that prepares each station for an upcoming frame. Start delimiter—Indicates the beginning of a frame by employing a signaling pattern that differentiates it from the rest of the frame. Frame control—Indicates the size of the address fields and whether the frame contains asynchronous or synchronous data, among other control information. Destination address—Contains a unicast (singular), multicast (group), or broadcast (every station) address. As with Ethernet and Token Ring addresses, FDDI destination addresses are 6 bytes long. Source address—Identifies the single station that sent the frame. As with Ethernet and Token Ring addresses, FDDI source addresses are 6 bytes long. Data—Contains either information destined for an upper-layer protocol or control information. Frame check sequence (FCS)—Is filed by the source station with a calculated cyclic redundancy check value dependent on frame contents (as with Token Ring and Ethernet). The destination address recalculates the value to determine whether the frame was damaged in transit. If so, the frame is discarded. End delimiter—Contains unique symbols; cannot be data symbols that indicate the end of the frame. Frame status—Allows the source station to determine whether an error occurred; identifies whether the frame was recognized and copied by a receiving station. †¢ †¢ Copper Distributed Data Interface Copper Distributed Data Interface (CDDI) is the implementation of FDDI protocols over twisted-pair copper wire. Like FDDI, CDDI provides data rates of 100 Mbps and uses dual-ring architecture to provide redundancy. CDDI supports distances of about 100 meters from desktop to concentrator. CDDI is defined by the ANSI X3T9. 5 Committee. The CDDI standard is officially named the Twisted-Pair Physical Medium-Dependent (TP-PMD) standard. It is also referred to as the Twisted-Pair Distributed Data Interface (TP-DDI), consistent with the term Fiber Distributed Data Interface (FDDI). CDDI is consistent with the physical and media-access control layers defined by the ANSI standard. The ANSI standard recognizes only two types of cables for CDDI: shielded twisted pair (STP) and unshielded twisted pair (UTP). STP cabling has 150-ohm impedance and adheres to EIA/TIA 568 (IBM Type 1) specifications. UTP is data-grade cabling (Category 5) consisting of four unshielded pairs using tight-pair twists and specially developed insulating polymers in plastic jackets adhering to EIA/TIA 568B specifications. Figure 8-11 illustrates the CDDI TP-PMD specification in relation to the remaining FDDI specifications. Internetworking Technologies Handbook 8-10 1-58705-001-3 Chapter 8 Fiber Distributed Data Interface Summary Figure 8-11 CDDI TP-PMD and FDDI Specifications Adhere to Different Standards FDDI Media Access Control (MAC) FDDI physical layer (PHY) FDDI Station Management (SMT) Twisted-pair wire PMD Single-mode fiber PMD Multimode fiber PMD Specification for CDDI Summary The Fiber Distributed Data Interface (FDDI) specifies a 100-Mbps token-passing, dual-ring LAN architecture using fiber-optic cable. FDDI is frequently implemented as a high-speed backbone technology because of its support for high bandwidth and greater distances than copper. Review Questions Q—What are the benefits of using FDDI instead of CDDI? A—Longer distance, no RFI, no EFI. Q—What role does the DAC play in the FDDI network? A—The concentrator is a dual-attachment station device and ensures that when single-attachment station devices—such as PCs—are turned off, they do not interrupt the network ring. Internetworking Technologies Handbook 1-58705-001-3 ct840811 8-11 Chapter 8 Review Questions Fiber Distributed Data Interface Internetworking Technologies Handbook 8-12 1-58705-001-3

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.